Maintenance Commands and Trouble-Clearing Aids 
Page 8-320
reset interface 
8
If the standby SPE is not refreshed when this command is executed, then the 
following message is displayed:
Standby SPE memory not refreshed; use the 
"refresh spe-standby" command.
If the standby SPE is not refreshed and the active SPE is hard selected via the 
SPE select switches when this command is executed, then the following 
message is displayed:
Active SPE locked via select switches; 
Standby SPE memory not refreshed
If the standby SPE is busy with another task, then the following message is 
displayed:
Standby SPE busy with another task; 
for information use "status system 1"
If the standby SPE is not available when this command is executed, then the 
following message is displayed:
Standby SPE not available;
for information use "status system 1"
If during the execution of a command a resource problem occurs that requires 
the user to restart the command, then the following message will be displayed:
Command resources busy; 
Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the 
following message will be displayed:
All maintenance resources busy; try again later
Output
If the reset interface command is successful, the following message will be 
displayed on the SAT:
Command successfully completed
If the reset interface command is unsuccessful, the following message will be 
displayed:
Error encountered, can’t complete request