DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-319
reset interface 
8
Parameters
Help Messages
If you press 
HELP
 after entering "reset interface," the following message displays:
Enter identifier: [cabinet(1)];carrier(A-B);position(1-2)
Error Messages
If the specified carrier is not the active PE, the following message will be 
displayed:
Command must be executed from active SPE
If the technician-entered cabinet and carrier is invalid for a PPN, the following 
message will be displayed:
Invalid port-network specified
If the technician-entered carrier is not a valid carrier, the following message will 
be displayed:
Invalid carrier specified
If the technician-entered carrier is not active, the following message displays:
Board invalid
If the specified carrier/position processor interface circuit pack is not inserted, 
but the specified carrier is active, the following error message will be displayed:
Processor Interface (TN765)
not started or is being started
If the command entered is in conflict with another currently executing command, 
then a message will be displayed showing the login id of the conflicting user and 
the conflicting command. The message is as follows:
’login id’:’command’ has a command conflict
If the standby is entering maintenance mode when this command is executed, 
then the following message is displayed:
Cannot interrupt Standby SPE while entering 
maintenance mode; please try later
location
The location (cabinet-carrier-position) of the processor interface (PI 
board). The position determines which processor interface circuit pack 
will be cleared. A position of 1 is the first processor interface in the 
carrier, while a position of 2 is the second processor interface in the 
carrier.