DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-528
status tsc-administered 
8
Defaults
None.
Parameters
Help Messages
If the system technician presses 
HELP
 after entering "status tsc-administered" the 
following message will be displayed:
Enter sig group # (1-8) /tsc index # (1-64),
[’print’]
Error Messages
If the format for the specified signaling group or the signaling group and TSC is 
incorrect, the following message is displayed:
Format invalid
If the specified signaling group number is out of range, the following message is 
displayed:
Signaling group invalid
If the specified signaling group is not administered, the following message is 
displayed:
No signaling group assigned
If the specified signaling group has no TSC assigned or the specified TSC is 
unadministered, the following message is displayed:
No TSC assigned
If the specified TSC number is out of range, the following message is displayed:
Tsc index invalid
If the software data cannot be sent to the SAT, the following message is 
displayed:
Error encountered, can’t complete request
If during the execution of a command a resource problem occurs that requires 
the user to restart the command, then the following message will be displayed:
Command resources busy;
Press CANCEL to clear, and then resubmit
signaling group #
An administered number associated with each signaling group.
tsc index
A number associated with each TSC in a signaling group.
print
This causes the report to be printed if a printer is linked to the SAT.