1.8.4 COM2 RS 232/422/485 mode selector (J2)
Users can use J2 to select among RS 232/422/485 modes for COM2.
The default setting is RS 232.
The default setting is RS 232.
Table 1.6: COM2 RS 232/422/485 mode selector (J2)
Function
Jumper Setting
RS232
(5-6) + (7-9) + (8-10) + (13-15) + (14-16) closed
RS422
(3-4) + (9-11) + (10-12) + (15-17) + (16-18) closed
RS485
(1-2) + (9-11) + (10-12) + (15-17) + (16-18) closed
1.8.5 LVDS Power 3.3V/5V selector (J6)
Table 1.7: LVDS Power 3.3V/5V selector (J6)
Function
Jumper Setting
5V
1
1-2 closed
*3.3V
1
2-3 closed
*default setting