This field let’s you insert a timing delay between the CAS and RAS strobe signals, used when 
DRAM is written to, read from, or refreshed.    Fast gives faster performance; and Slow gives 
more stable performance.    This field applies only when synchronous DRAM is installed in 
the system.     
Row Precharge Time 
If an insufficient number of cycles is allowed for the RAS to accumulate its charge before 
DRAM refresh, the refresh may be incomplete and the DRAM may fail to retain date.    Fast 
gives faster performance; and Slow gives more stable performance.    This field applies only 
when synchronous DRAM is installed in the system. 
 
3-12 
Thermal Throttling Options   
Phoenix – AwardBIOS CMOS Setup Utility
  
Thermal Throttling Options  
 
Item Help 
 
    
CPU  Thermal-Throttling                Disabled 
CPU  Throttling  Temp                    70 
    CPU  Throttling  Duty                    50% 
  Menu  Level  
↑↓→← Move Enter:Select +/-/PU/PD:Value F10:Save ESC:Exit  F1:General Help 
F5:Previous  Values    F6:Optimized  Defaults   F7:Standard  Defaults 
 
3-13 Load Fail-Safe Defaults 
Load Fail-Safe Defaults 
When you press <Enter> on this item, you get a confirmation dialog box with a message 
similar to: 
Load Fail-Safe Defaults (Y/N)? N 
Pressing <Y> loads the default values that are factory settings for stable performance system 
operations. 
3-14 Load Optimized Defaults 
Load Optimized Defaults 
When you press <Enter> on this item, you get a confirmation dialog box with a message 
similar to: 
Load Optimized Defaults (Y/N)? N 
Pressing <Y> loads the default values that are factory settings for optimal performance 
system operations. 
 
3-15 Password Settings 
Phoenix – AwardBIOS CMOS Setup Utility
  
Password Settings  
 
Item Help 
     
   Set  Supervisor  Password            Press  Enter  
   Set  User  Password                  Press  Enter     
 
  Menu  Level  > 
↑↓→← Move Enter:Select +/-/PU/PD:Value F10:Save ESC:Exit  F1:General Help 
F5:Previous  Values    F6:Optimized  Defaults   F7:Standard  Defaults 
You can set either supervisor or user password, or both of them.    The differences are: 
Supervisor password:    Can enter and change the options of the setup menus. 
User password:
 
Can only enter but do not have the right to change the options of the 
setup menus.    When you select this function, the following message will appear at the