页码 146
3 - 14
The default values for these entries are as follows:
MedState=25%
This sets the Low Battery point to 25%. When the battery hits the percentage charge specified 
here, the user is notified.
LowState=10%
This sets the Critical Battery point to 10%. When the battery hits the percentage charge 
specified here, the user is notified.
Note: Warnings do not appear when the terminal is on external power.
Setting Critical and Low Battery Points
Developers can reset the battery parameters in the registry from 0 (no warning) to 99 (would nearly 
always warn). You can review and set these battery points in the RegEdit Power Tool. 
1.
Tap Start > Power Tools > RegEdit
2.
Drill down to HKEY_LOCAL_MACHINE > ControlPanel > Power.
3.
Tap the Value Name to change the Value Data. 
You can reset the Value Data from 0 (no warning) to 99 (would nearly always warn). 
4.
Tap OK to save changes.
www.honeywellaidc.com
.
Checking Battery Power
Tap Start Settings System > Power.  
Note: The Backup Battery gauge registers either 0% or 100%. The percentage is not an indication of the level of 
charge remaining on the backup battery. An installed and functional battery registers 100%. A total discharge 
or a battery error registers 0%.
Note: Tapping the battery icon at the top of the screen does not open the Power applet with this version of Microsoft 
Windows Mobile.