Chapter 5 Troubleshooting and Diagnostics
Handling Alarms
5-9
The Event Log screen appears (
Figure 5-11
).
RIC-155
Event Log
Source Alarm Status Severity Time Date
4 Event Loss Of Signal ON Major 2:11:13 12/06/03
5 Loss Of Frame ON Major 3:52:31 13/06/03
| 3 Line Signal Degraded Error OFF Minor 13:45:27 13/06/03
V 16 Software download OFF Warning 14:52:17 13/06/03
2 Line Excessive Error Defect ON Major 20:46:02 13/06/03
54 Buffer Overflow OFF Event 9:13:20 14/06/03
ESC-prev.menu; !-main menu; &-exit;
Source Alarm Status Severity Time Date
4 Event Loss Of Signal ON Major 2:11:13 12/06/03
5 Loss Of Frame ON Major 3:52:31 13/06/03
| 3 Line Signal Degraded Error OFF Minor 13:45:27 13/06/03
V 16 Software download OFF Warning 14:52:17 13/06/03
2 Line Excessive Error Defect ON Major 20:46:02 13/06/03
54 Buffer Overflow OFF Event 9:13:20 14/06/03
ESC-prev.menu; !-main menu; &-exit;
Figure 5-11. Event Log Screen
To clear the event log:
1. From the System Monitoring menu (
1. From the System Monitoring menu (
), select Clear Event Log.
RIC-155 displays a confirmation message at the bottom of the screen:
Request to clear log file! Are you sure? (Y/N):
2. Type Y.
All the log file entries are deleted from the system log file.
Configuring Alarm Severity
Severity of the RIC-155 alarms can be defined by the user. Configuration of the
alarm severity is performed via the System Alarms menu.
alarm severity is performed via the System Alarms menu.
To configure the alarm severity:
1. From the System Configuration menu, select Alarm Configuration.
1. From the System Configuration menu, select Alarm Configuration.
The Alarm Configuration menu appears (
RIC-155
Alarm Configuration
System Alarms
System Alarms
[]>
Default Alarms Setting
>
Please select item <1 to 2>
ESC-prev.menu; !-main menu; &-exit;
Figure 5-12. Alarm Configuration Menu
2. From the Alarm Configuration menu, select System Alarms.
System Alarms menu appears (
3. From the System Alarms menu, select Severity column of the alarm that you
intend to configure by moving cursor up/down or left/right.
4. Select a new alarm severity value by typing 1 (Minor) or 2 (Major).