Section 12   Bus State Controller (BSC) 
 
 
Rev. 4.00  Sep. 14, 2005  Page 321 of 982 
 
 REJ09B0023-0400 
12.5 Operating 
Description 
12.5.1 
Endian/Access Size and Data Alignment 
This LSI supports big endian, in which the 0 address is the most significant byte (MSByte) in the 
byte data.  
Three data bus widths (8 bits, 16 bits, and 32 bits) are available for normal memory and byte-
selection SRAM. Two data bus width (16 bits and 32 bits) are available for SDRAM. Data bus 
width for MPX-IO is fixed to 32 bits. Data alignment is performed in accordance with the data bus 
width of the device. This also means that when longword data is read from a byte-width device, 
the read operation must be done four times. In this LSI, data alignment and conversion of data 
length is performed automatically between the respective interfaces. 
Table 12.5 through 12.7 show the relationship between device data width and access unit. 
Table 12.5  32-Bit External Device Access and Data Alignment 
 
Data Bus 
Strobe Signals 
Operation 
D31 to 
D24 
D23 to 
D16 
D15 to 
D8 D7 
to 
D0
WE3
DQMUU 
WE2
DQMUL 
WE1
,  
DQMLU 
WE0
,  
DQMLL 
Byte access  
at 0 
Data 
7 to 0 
 
 
 Assert   
 
 
Byte access  
at 1 
 Data 
7 to 0 
 
 
 Assert  
 
Byte access  
at 2 
 
 Data 
7 to 0 
 
 
 Assert  
Byte access  
at 3 
 
 
 Data 
7 to 0 
 
 
 Assert 
Word access 
at 0 
Data  
15 to 8 
Data  
7 to 0 
 
 Assert Assert   
 
Word access 
at 2 
 
 Data 
15 to 8 
Data 
7 to 0 
 
 Assert 
Assert 
Longword 
access at 0 
Data  
31 to 24 
Data  
23 to 16 
Data 
15 to 8 
Data 
7 to 0 
Assert Assert Assert Assert