19.   Display Unit (DU) 
Rev.1.00  Jan. 10, 2008  Page 953 of 1658 
REJ09B0261-0100 
 
19.4.15
  Double Buffer Control 
The double buffer control of the display unit (DU) includes two types of functions, which are a 
manual display change mode in which display switching is all controlled by software, and an auto 
display change mode to realize blinking. 
In the case of manual display change mode, the display change is performed in frame units for 
non-interlaced and interlaced sync display, and in field units for interlaced sync & video display. 
In the case of auto display change mode, all switching is performed in field units. 
Manual Display Change Mode: In manual display change mode, display frame switching is 
controlled by software. Display switching can either be performed by software using the PnDC bit 
in PnMR, or by setting the buffer 0 or buffer 1 start address in PnDSA0R and PnDSA1R indicated 
by the DFBn bit in DSSR. 
When making a transition from this mode to another mode, the PnDC bit should always be set to 1 
first. 
The following shows a control example for the manual display mode. 
VSYNC
(Non-interlaced)
Display screen 
operation
 
A0 display
A0 display
A1 display
First frame
Second frame
Third frame
Interrupt 
processing
Interrupt 
processing
Interrupt 
processing
Start of 
transfer
Start of 
transfer
 
CPU operation
 
A0: Display area start address 0
A1: Display area start address 1
VBK: VBK bit in DSSR
Transfer of display data for A1
Transfer of display data for A0
Display is switched by 
the PnDC bit or DSAR 
at the falling edge of VSYNC.
Display data 
transfer by a 
VBK interrupt
If display data 
transfer for B1 has 
not been completed, 
a VBK  interrupt is 
ignored.
PnDC bit is set to 1, 
       or
DSAR address is 
set.
The PnDC bit is 
set by a transfer 
end interrupt.
 
 
Auto Display Change Mode: For information on the auto display change mode, refer to section 