Renesas SH7781 用户手册

下载
页码 1692
19.   Display Unit (DU) 
Rev.1.00  Jan. 10, 2008  Page 954 of 1658 
REJ09B0261-0100 
 
19.4.16
  Sync Mode 
In order to facilitate synchronization with external equipment, in addition to master mode, a TV 
synchronization function is provided. Selection of master mode and TV sync mode is performed 
using the TVM bit in DSYSR. Regardless of the synchronization method, the position of the 
falling edge of the vertical sync signal (VSYNC) set by VSPR is detected and is reflected in the 
FRM bit and VBK bit in DSSR. 
Master Mode (Internal Sync Mode): By setting the period and pulse width of the horizontal and 
vertical sync signals (HSYNC, VSYNC) in the display timing generation register, the 
corresponding waveforms are output. Also, display data is output in sync with these signals.  
When in interlaced sync mode and interlaced sync & video mode, a signal is output to the ODDF 
pin indicating odd/even fields. 
TV Sync Mode (External Sync Mode): In TV sync mode, display data is output in sync with a 
horizontal sync signal and vertical sync signal (EXHSYNC, EXVSYNC) input from a TV, video, 
or other external sync signal generation circuit. Display data is output with reference to the falling 
edge of the EXHSYNC signal and the rising edge of the EXVSYNC signal. 
The horizontal sync signal, vertical sync signal, and clock signal from the external sync signal 
generation circuit are input to the 
HSYNC, VSYNC, and DCLKIN pin, respectively. CSYNC is at 
high level. When in interlaced sync mode and interlaced sync & video mode, a signal should be 
input to the ODDF pin indicating odd/even fields. When in non-interlaced mode, the input to the 
ODDF pin should be fixed at low level or at high level. 
When operating the unit in TV sync mode also, values must be set in HCR, HSWR, VCR, and 
VSPR (display timing generation registers). 
When the EXVSYNC signal is input, either before or after completion of display of the display 
size portion set in the display unit (DU), the display unit (DU) performs vertical display 
completion operation and transitions to control for the next screen. When the EXVSYNC signal is 
not input, the unit continues to wait for the EXVSYNC signal while remaining in the vertical 
blanking interval (auto-control is not performed). Similarly, when the EXHSYNC signal is input 
the display unit (DU) performs horizontal display completion operation and transitions to control 
for the next raster line; but if the EXHSYNC signal is not input, the unit continues to wait for the 
EXHSYNC signal while remaining in the horizontal blanking interval (auto-control is not 
performed).