2 - 1 4   O v e r v i e w  
SG  20 00  Ins tal la tion  and  O pera tion  M anua l  
 
L ev e l  Co n tro l 
The gain of hybrid IC amplifiers varies with temperature. In addition, changes in system channel 
loading and/or splices in the fiber link can change the level of the received signal. 
The standard TCU board compensates for anticipated hybrid gain changes by sensing housing 
temperature and signaling needed changes to the RF attenuator. 
The ADU board, an optional plug-in module, monitors the amplitude of a selected pilot frequency. 
The pilot frequency is an available analog television channel not scrambled by the sync suppression 
method. Any changes in amplitude are fed back to the RF attenuator that makes appropriate 
corrections. 
The input to the ADU contains a JXP-* pad. The factory-installed value of this pad is 6 dB (JXP-6) 
for bridger level outputs and 0 dB (JXP-ZX) for trunk level outputs. Under normal conditions, it 
should not be changed. 
O p t io ns   and   Acc es so rie s  
Table 2-3 provides a list of options and accessories for the SG 2000: 
T a b l e   2 - 3    
O p t i o n s   a n d   a c c e s s o r i e s  
Model Desc ription
Functio n 
ADU-* 
Automatic drive 
unit 
This option automatically adjusts gain by monitoring changes 
in the level of the selected pilot carrier. Either an ADU or TCU 
must be installed. 
TCU 
Thermal control 
unit 
The TCU controls amplifier gain for changes in hybrid gain at 
the sensed temperature. 
JXP-*A 
Fixed 
attenuator 
Attenuator pads are used to adjust amplifier levels and are 
available in 1 dB steps from 1 through 24 dB. The appropriate 
value must be installed. 
JXP-ZX 
0 dB attenuator 
This attenuator is used in place of JXP-*A pads when no 
attenuation is needed. 
FTEC 
Crowbar 
overvoltage 
protection 
The FTEC is an electronic crowbar/surge protector that can be 
used to replace the existing 230-volt gas discharge surge 
protector. 
LL-SG2 
LIFELINE 
module 
This module enables the system operator to monitor the SG2 
from a remote location. See Section 5, “Operation” for 
parameters monitored. Several frequencies are available. See 
the product catalog for additional information. 
GFAL 
Test probe 
This probe is used to evaluate node performance. 
F/JXP 
Injection probe 
This probe is used to inject a signal for test purposes.