Motorola SG 2000 用户手册

下载
页码 105
   
O v e r v i e w  
2 - 1 5  
 
SG  20 00  Ins tal la tion  and  O pera tion  M anua l 
Model Desc ription 
Functio n 
SG2-MCB 
Manual control 
board 
This board locally controls the ingress switch and 
receiver/transmitter A/B redundant switching if the node is not 
equipped with status monitoring. 
SG2-SB/* 
Strand bracket 
Bracket for hanging a strand mounted node. 
SG2-PS 
Power supply 
Provides the 
+
24 V and 
+
5 V dc supply to the station. It has an 
extended voltage range and is power-factor corrected. 
SG2-PS2 
Power supply 
Provides the 
+
24 V and 
+
5 V dc supply to the station. 
SG2-
SERCAB/* 
Service cable 
A 6-fiber service cable that is available with SC/APC or 
FC/APC connectors. 
SG2-FE-
*/750 
Forward 
equalizers 
Used to increase output tilt at one or more ports in a 750 MHz 
system. They are available in 1 dB increments from 2 dB 
through 6 dB. 
SG2-FE-
*/870 
Forward 
equalizers 
Used to increase output tilt at one or more ports in an 870 
MHz system. They are available in 1 dB increments from 2 dB 
through 6 dB. 
SG2-IS 
Ingress switch 
This switch enables the operator to troubleshoot without 
shutting down the return path. It requires the use of either the 
LL-SG2/* or the SG2-MCB. 
SG2-LR 
Lightwave 
receiver 
This receiver converts the received optical signal to 
broadband RF. 
DS-SG2-DRRB Digital return 
redundancy 
board 
This board provides the redundant input to a 
DS-SG2-DRT/A-2X digital return transmitter. One DRRB is 
used for each -2X transmitter. 
SG2-* 
Analog return 
transmitters 
Table 2-1 identifies and describes the five optical analog 
return-path transmitters. 
DS-SG2-DRT* Digital return 
transmitters 
Table 2-2 identifies all models of the optical digital return-path 
transmitters. Section 5, “Operation,” provides detailed 
information and block diagrams for each series of digital 
transmitters.