MRV Communications TS700/G 用户手册

下载
页码 77
M R V   C o m m u n i c a t i o n s ,   I n c .   –   I n s t a l l a t i o n   M a n u a l  
9 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
That’s what 
happens when 
the air channel 
is interrupted. 
F/O
 
 
Network
RF Transceiver 
10/100TX-100FX 
Media Converter
 
Switch  
10/100 Base-T 
MC
10 Base-T  
STP 
F/O
 
Main
TS 
TS 
IR = 100 Mbps 
 
Network
Main
RF Transceiver 
RF = 2-10 Mbps 
F/O 
F/O 
10 Base-T  
STP 
Redundant 
Redundant 
Figure 1.5a:  TereScope800/155 F - & Fusion System Connection
For a description of the Back Panel and all the functions, see Paragraph B table 3, and 
Paragraph C Figure 1.4 – TS800 with Fusion model, page 8.  
 
Fusion Operation Mode 
When at least one of the air channels (IR) is cut for more than one second or drops to 
approximately 60 mV at the display readout: 
1.  TereScope switches to Fusion mode 
2.  Data is transmitted from Main module to Redundant module without passing 
through the air channel 
3.  The signal is converted to 10Base-T by the Switch and the data Rate decreases 
to 2-10 Mbps 
The system switches back to IR channel (TereScope) only   when the display readout on both 
sides increases to approximately 150 mV. 
 
Note:  To activate the Fusion option, set DIP Switch toggle 5 to the ON position.