MRV Communications TS700/G 用户手册

下载
页码 77
M R V   C o m m u n i c a t i o n s ,   I n c .   –   I n s t a l l a t i o n   M a n u a l  
11 
D.  TS700/100 - Fast-Ethernet System 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Figure 1.6:  TS700/100 Model Back Panel
 
Back Panel Description 
Table 4:  TS700/100 Back Panel Controls, Interfaces, and Indicators 
 
Power
 
Power source Terminal Block (Main or UPS) 
AC power supply (100 to 240 Vac) or DC power 
supply (24 to 60 Vdc). 
 
100Base-TX 
 
Copper interface (RJ45) for STP cables.  
MDI-X connection (TX: pins 3,6 and RX: pins 1,2). 
Connection to the peripheral equipment.  
This connector can be used for Power-over-Ethernet 
(PoE) but only with the Low Voltage TereScope version 
(TS100/A/FET/V3). The standard power for PoE is 
36-57 Vdc. However, the TS700/100 can operate with 
20-60 Vdc. 
See appendix I. 
 
Management 
(Optional) 
 
Connection to 10Base-T SNMP management 
interface. (To be ordered separately) 
 
Connectors
 
Dry Contacts 
There are 2 pairs of dry contact indicators available, 
one for Air RX Link LED (Pins 1 and 2), and the 
other for 100BaseT LED (Pins 3 and for).  Dry 
contacts are normally closed (25 ohms), and open in 
an alarm condition