M R V   C o m m u n i c a t i o n s ,   I n c .   –   I n s t a l l a t i o n   M a n u a l  
24 
Infrastructure 
The only infrastructure required for operating the transceiver and linking 
the sites is Power and Data/Signal connection to the peripheral 
networking equipment. This must be ready prior to the airlink installation
IN OUTDOOR INSTALLATIONS, USE SHIELDED AND 
WEATHERPROOF MATERIALS (CABLES, INLETS, AND 
CONNECTORS) COMPLIANT TO THE SAFETY STANDARD IN 
FORCE.  
 
Power 
 
Source 
 
The power requirement for standard units is 100-240VAC @ 
50/60Hz - 10W.  
Note: Units requiring low Voltage: 24-60 VDC - 10W can be factory 
set upon request.  
It is recommended to use a Surge Suppression System to avoid 
damage to the equipment when power supply is unstable. 
Protection should be at least 25,000A. 
 
Cabling
 
 
 
Standard 3-conductor power cords are required. (See Safety 
requirements, Page iv)  
Data/Signal Cabling 
 
1.   For TS700/155 ,  TS700/G, TS800/155 , TS800/155-F 
 
 
Type  
For connecting the Transceiver to the peripheral equipment, a dual-
fiber cable is required (one fiber for transmission, the other for 
reception). The standard recommended cable is MM 62.5/125 µm 
fiber or SM 9/125 µm for fiber. 
 
Connectors  
Each fiber should be terminated with the ordered type of connector 
on the transceiver end (SC, ST). 
 
Optical Fiber testing. 
The cabling installer must specify the attenuation of each fiber 
installed.
 