MRV Communications TS700/G 用户手册

下载
页码 77
M R V   C o m m u n i c a t i o n s ,   I n c .   –   I n s t a l l a t i o n   M a n u a l  
26 
Bench Test 
It is always easier and more convenient to locate a failure and solve a 
problem in a lab on a bench than on a roof under bad conditions. 
Accordingly, it is strongly recommended to perform a bench test with 
all the modules prior to installation in order to check the equipment 
compatibility and to validate the configuration. 
See Unpacking Instructions in Appendix C. 
1 – TS700/155,  TS800/155, and TS800/155-F
 
Compatibility 
 
 
Peripheral equipment 
Check the operation of the peripheral equipment connected with cables (see 
Configuration 1 below). 
 
Interfaces 
Check the specifications compatibility (type, wavelength, receiver range, output 
power, data rate) between the TereScope and the peripheral equipment interfaces. 
Test equipment 
Chose an appropriate Bit Error Rate (BER) tester for checking the physical link 
quality. A portable one is preferable since it is more convenient for use in the field.  
 
For example: the OC3 port plus SONET and ATM analyser manufactured by 
Fluke. 
A ping test or a file transfer between two workstations - connected to the 
networking equipment - is useful and easy to do for testing the performance of the 
whole configuration. 
Setup 
Data Rate DIP Switch Toggle 
According to the application in use, set the switch toggles as indicated in the 
following table: (In TS800/155 and TS800/155-F set the DS1 toggles) 
 
 
 
Chapter