Troubleshooting Guide 6-11
T
roubleshooting
Initiating and Terminating Tests from the Modem’s Front Panel
To initiate a test from the modem’s front panel:
1) Press 
 until you reach the TEST OPTS category.
2) Press 
 until you reach Test=End Test.
3) Press 
 until Test=LAL (for example)
4) Press 
 to start the test.
To terminate a test from the modem’s front panel:
1) Press 
 until Test=End Test.
2) Press 
 to stop the test.
Synchronous Data Compression (SDC) Testing
When performing diagnostic tests in SDC mode, note the following:
• All tests are supported
• When initiating the following “online” tests:
— Remote digital loopback
— Remote digital loopback pattern
— Data mode pattern
— Local digital loopback
during SDC connection, the modem falls back to Direct mode (Mode=Direct, 
AT
*
SM) to run the test. If the modem is set for internal timing 
(Clock=Internal, AT&X) the DTE clock is changed to match the DCE rate. If 
the modem is set for external timing (Clock=External, AT&X), the clock rate 
provided may not match the DCE rate and the test will not function. (Set 
Clock=Internal temporarily to complete testing, and then reset to External.)
• To test the synchronous data path’s integrity while running loopback tests, set 
the modem for one of the asynchronous buffered modes (Mode=Normal, 
Reliable, Auto Reliable, or Speed Auto Reliable).