Chapter 15. Synchronous DRAM Controller Module
15-7
SDRAM Controller Operation
10–8
CBM Command and bank MUX [2:0]. Because different SDRAM configurations cause the command and bank select
lines to correspond to different addresses, these resources are programmable. CBM determines the addresses onto
which these functions are multiplexed.
which these functions are multiplexed.
This encoding and the address multiplexing scheme handle common SDRAM organizations. Bank select bits
include a base bit and all address bits above for SDRAMs with multiple bank select bits.
include a base bit and all address bits above for SDRAMs with multiple bank select bits.
7
—
Reserved, should be cleared.
6
IMRS Initiate mode register set (
MRS
) command. Setting IMRS generates a
MRS
command to the associated SDRAMs.
In initialization, IMRS should be set only after all DRAM controller registers are initialized and
PALL
and
REFRESH
commands have been issued. After IMRS is set, the next access to an SDRAM block programs the
SDRAM’s mode register. Thus, the address of the access should be programmed to place the correct mode
information on the SDRAM address pins. Because the SDRAM does not register this information, it doesn’t
matter if the IMRS access is a read or a write or what, if any, data is put onto the data bus. The DRAM controller
clears IMRS after the
information on the SDRAM address pins. Because the SDRAM does not register this information, it doesn’t
matter if the IMRS access is a read or a write or what, if any, data is put onto the data bus. The DRAM controller
clears IMRS after the
MRS
command finishes.
0 Take no action
1 Initiate
1 Initiate
MRS
command
5–4
PS
Port size. Indicates the port size of the associated block of SDRAM, which allows for dynamic sizing of
associated SDRAM accesses. PS functions the same in asynchronous operation.
00 32-bit port
01 8-bit port
1x 16-bit port
associated SDRAM accesses. PS functions the same in asynchronous operation.
00 32-bit port
01 8-bit port
1x 16-bit port
3
IP
Initiate precharge all (
PALL
) command. The DRAM controller clears IP after the
PALL
command is finished.
Accesses via IP should be no wider than the port size programmed in PS.
0 Take no action.
1 A
0 Take no action.
1 A
PALL
command is sent to the associated SDRAM block. During initialization, this command is executed
after all DRAM controller registers are programmed. After IP is set, the next write to an appropriate SDRAM
address generates the
address generates the
PALL
command to the SDRAM block.
2–0
—
Reserved, should be cleared.
Table 15-5. DACRn Field Descriptions (continued)
Bit
Name
Description
CBM
Command Bit
Bank Select Bits
000
17
18 and up
001
18
19 and up
010
19
20 and up
011
20
21 and up
100
21
22 and up
101
22
23 and up
110
23
24 and up
111
24
25 and up