Motorola MCF5281 用户手册

下载
页码 816
33-8
MCF5282 User’s Manual
MOTOROLA
 
QADC Electrical Characteristics  
Input Voltage
V
INDC
V
SSA
–0.3
V
DDA
 + 0.3 
V
Input High Voltage, PQA and PQB
V
IH
0.7 (V
DDA
)
V
DDA
 
+ 0.3
V
Input Low Voltage, PQA and PQB
V
IL
V
SSA
 
– 0.3
0.4(V
DDA
)
V
Input Hysteresis, PQA, PQB
 3
V
HYS
0.5
V
Output High Voltage, PQA/PQB 
3
I
OH
 = TBD
V
OH
VDDH-0.8

V
Analog Supply Current
Normal Operation
 4
Low-Power Stop
I
DDA

5.0
10.0
mA
µA
Reference Supply Current, DC
Reference Supply Current, Transient
I
REF
I
REF

250
2.0
µA
mA
Load Capacitance, PQA/PQB
C
L
50
pF
Input Current, Channel Off
 5
I
OFF
-200
200
nA
Total Input Capacitance
 6
PQA Not Sampling
PQB Not Sampling
Incremental Capacitance added during sampling
C
IN

15
10
5
pF
1
QADC converter specifications are only guaranteed for VDDH and VDDA = 5.0V +/- 0.5V. VDDH and VDDA may be 
powered down to 2.7V with only GPIO functions supported.
2
To obtain full-scale, full-range results, V
SSA
 
≤ V
RL
 
≤ V
INDC
 
≤ V
RH
 
≤ V
DDA
3
Parameter applies to the following pins:
Port A: PQA[4:3]/AN[56:55]/ETRIG[2:1], PQA[1:0]/AN[53:52]/MA[1:0]
Port B: PQB[3:0]/AN[3:0]/AN[Z:W]
4
Current measured at maximum system clock frequency with QADC active.
5
Maximum leakage occurs at maximum operating temperature. Current decreases by approximately one-half for each 8 
to 12° C, in the ambient temperature range of 50 to 125 °C.
6
This parameter is characterized before qualification rather than 100% tested.
Table 33-6. QADC Electrical Specifications (Operating) 
1
 (Continued)
(V
DDH 
and V
DDA 
= 5.0 V
dc
 
±
 0.5V, V
DD 
= 2.7-3.6V, V
SS
 and V
SSA
 = 0 V
dc
, FQCLK = 2.0 MHz, TA within operating temperature range)
Parameter
Symbol
Min
Max
Unit