Using Interrupts on the MVME172
http://www.mcg.mot.com/literature
B-3
B
3.
Set up an interrupt handler routine:
Step
Action and Reference
Your interrupt handler should include the following features.
1
Be sure the MC68060 vector base register is set up. Set the 
proper MC68060 exception vector location so the processor 
vectors to your interrupt handler location. You can determine 
the proper exception vector location to set from the MC68060 
vector base register, the VMEchip2 base register, and Table 2-3, 
the Local Bus Interrupter Summary, in Chapter 2, from which 
you can determine the actual interrupt vector given on a Tick 
Timer 1 interrupt. Lower the MC68060 mask so the interrupt 
level you programmed is accepted. The interrupt handler itself 
should include the following (steps 2 through 5). 
2
Confirm the Tick Timer 1 interrupt occurred, by reading the 
status of bit 24 of the Interrupter Status Register at $FFF40068. 
A high indicates an interrupt present. 
3
Clear Tick Timer 1 interrupt by writing a one to bit 24 of the 
Interrupt Clear Register at $FFF40074. 
4
Increment a software counter to keep track of the number of 
interrupts, if desired. Output a character or some other action 
(such as toggling the 
FAIL
 LED) on an appropriate count, such 
as 1000. 
5
Return from exception.