Motorola MVME172 用户手册

下载
页码 354
Software Support Considerations
http://www.mcg.mot.com/literature
1-51
1
MPU Off-board Error
Description:
An error occurred while the MPU was attempting to access an off-board 
resource.
MPU Notification:
TEA is asserted during off-board access.
Status:
Bit 8 of the MPU Status and DMA Interrupt Count Register. Address 
$FFF40048.
Comments:
This can be caused by a VMEbus time-out, a VMEbus BERR, or an 
MVME172 VMEbus access time-out. The latter is the time from when the 
VMEbus has been requested to when it is granted.
MPU TEA - Cause Unidentified
Description:
An error occurred while the MPU was attempting an access.
MPU Notification:
TEA is asserted during an MPU access.
Status:
Bit 10 of the MPU Status and DMA Interrupt Count Register at address 
$FFF40048 in the VMEchip2.
Comments:
No status was given as to the cause of the TEA assertion.
MPU Local Bus Time-out
Description:
An error occurred while the MPU was attempting to access a local 
resource.
MPU Notification:
TEA is asserted during the MPU access.