Board Description and Memory Maps
1
and when VMEbus mastership has been granted. Because we have found 
in the past that some VME systems can become very busy, we recommend 
this time-out be set at a large value, such as 32 msec.
Once the VMEbus has been granted, a third timer takes over. This is the 
global VMEbus timer. This timer starts when a transfer actually begins 
(DS0 or DS1 goes active) and ends when that transfer completes (DS0 or 
DS1 goes inactive). This time should be longer than any expected 
legitimate transfer time on the bus. We normally set it to 256 
µ
sec. This 
timer can also be disabled for debug purposes. Before an MVME172 
access to another MVME172 can complete, however, the VMEchip2 on 
the accessed MVME172 must decode a slave access and request the local 
bus of the second MVME172. When the local bus is granted (any 
in-process onboard transfers have completed) then the local bus timer of 
the accessed MVME172 starts. Normally, this is also set to 256 
µ
sec. 
When the memory has the data available, a transfer acknowledge signal 
(TA) is given. This translates into a DTACK signal on the VMEbus which 
is then translated into a TA signal to the first requesting processor, and the 
transfer is complete. If the VMEbus global timer expires on a legitimate 
transfer, the VMEbus to local bus controller in the VMEchip2 may become 
confused and the VMEchip2 may misbehave; therefore, the bus timers’ 
values must be set correctly. The correct settings depend on the system 
configuration.
MVME172 MC68060 Indivisible Cycles
The MC68060 performs operations that require indivisible 
read-modify-write (RMW) memory accesses. These RMW sequences 
occur when the MMU modifies table entries or when the MPU executes a 
TAS, CAS, or CAS2 instruction. TAS cycles are always single-address 
RMW operations, while the CAS, CAS2, and MMU operations can be 
multiple-address RMW cycles. The VMEbus does not support 
multiple-address RMW cycles and there is no defined protocol for 
supporting multiple-address RMW cycles which start onboard and then 
access off-board resources. The MVME172 does not fully support all 
RMW operations in all possible cases.