Installation
Manual No. 775051
2-13
SCSI Termination
Each end of a SCSI bus must be terminated to maintain proper voltage levels 
for SCSI control and data signals. The device used for this purpose is called 
a terminator. Termination devices can be built into a controller, a SCSI 
device, or attached to the end of a SCSI bus. 
The AcceleRAID 352 controller is equipped with automatic SCSI bus 
termination circuitry. If the controller is at the end of a SCSI bus, it 
automatically enables on-board termination. The controller can also detect 
whether single-ended (SE) or low-voltage differential (LVD) termination is 
required, and can automatically configure the appropriate termination type.
The end of the SCSI bus farthest from the controller must be terminated if 
SCSI devices are connected to the SCSI channel. See Figure 2-10 for an 
example of a SCSI device configuration connected to the internal SCSI 
channel.
Note
When connecting SCSI devices, it is better to 
terminate the ends of the SCSI bus itself, rather than 
to terminate the end devices on the bus. This allows 
hot swap devices to be added or removed from the 
SCSI bus without affecting termination.