Lucent Technologies 6000 用户手册

下载
页码 586
4-116
MAX 6000/3000 Network Configuration Guide
Configuring Individual WAN Connections
Configuring POTS capability on the MAX 6000 and MAX 3000
Phone Number=5556602
Dst Slot=3
Dst Port=2 
Line Status
From Main Status Menu > Analog FXS > Line Status, you can monitor the activity of each 
port. Each port can be represented by one of the following characters. 
For example, the status windows in Figure 4-19 indicate that all 8 POTS ports are idle.
Figure 4-19. MAXPOTS Line Status display
Call Detail Reporting
The MAX logs the standard Call Detail Reporting (CDR) records. Specifically, the unit 
supports the ANSWER, ORIGINATE, and CLEAR records. Note that the standard method 
applies for identifying calls that are not picked up, that is, the unit logs a CLEAR record 
without an associated ANSWER record.
For more information about Call Detail Reporting, see the MAX Administration Guide.
Character
Description
– (dash)
idle
. (period)
off-hook
D
dialing
R
ringing
=
connected