ATTO Technology 2390C/R/D 用户指南

下载
页码 51
21
ATTO Technology Inc. FibreBridge Installation and Operation Manual
Email messages provide error notification
Email notification allows the FibreBridge to send an 
Email message to you, a network administrator or 
other users when certain events occur. Serious error 
messages are sent immediately, while messages for 
less serious errors are sent every 15 minutes.
You may send Emails to up to five Email addresses 
and designate which conditions prompt each Email 
notification. 
When an event occurs that has been designated as 
requiring Email notification, the FibreBridge sends the 
message; it cannot respond to a rejection by a server 
for an invalid address. Ensure all Email addresses 
typed in are valid.
Each Email is time stamped when it leaves as part of 
the SMTP header information as shown in Exhibit 3.0-
5.
1
If you are not already in the ExpressNAV 
interface, type the IP address of your 
FibreBridge in a standard browser as found in 
Enter 
Here, type in your user name and password, 
and click 
OK.
2
On the left hand menu, click 
Remote Mgt.
3
The 
Remote Management page appears.
4
Click on the 
enabled radio button next to the 
Email Notification heading.
5
Type in the sender address (Emails show this 
name in the 
From field)
6
Type in the SMTP Server IP address
7
Type in the user name and password of your 
SMTP Email account if your server requires it
8
Type in up to five Email addresses
9
Choose 
AllInformational, Warning, or 
Critical for each Email address.
10 When all information is typed in, click 
Submit.
Temperature 
Warning
Yes
Yes
Unit’s internal temperature has increased to at or 
within the unit’s maximum operating temperature 
less the unit’s temperature warning offset or 
decreased to at or within the unit’s minimum 
operating temperature plus the unit’s temperature 
warning offset.
Unit Attention
Info
No
Yes
A SCSI command discovers a unit attention 
condition has occurred.
Unit Power On
Info
Yes
Yes
The unit has been powered up.
Voltage
Info
Yes
Yes
A monitored voltage level has increased or 
decreased to within standard operating ranges.
Voltage 
Critical
Yes
Yes
A monitored nominal voltage level has increased 
or decreased beyond the percentages listed 
below:
Level
... 
VDDA
 ......
VDDB
..... .
VDDC
........
VDDD
.............
3.30V
.........
2.50V
........
1.50V
.........
1.35V
Low
.......
5%
..............
4%
............
5%
.........,..
4.5%
High
.... 
8%
............ 
5%
..... ....
 5%
............ 
5%
Voltage 
Warning
Yes
Yes
A monitored nominal voltage level has increased 
or decreased beyond the percentages listed 
below:
Level
... 
VDDA
 ......
VDDB
..... .
VDDC
........
VDDD
.............
3.30V
.........
2.50V
........
1.50V
.........
1.35V
Low
.......
3%
..............
3%
..........
3%
.........,..
3%
High
..... 
5%
.......... 
3.5%
... ......
 3%
.......... 
3%
Event
Severity
Level
Extended 
Traps disabled
Extended 
Traps enabled
Explanation