EX2100 Specification
Description
Power Conversion Module (PCM)
Single bridge rating
1,000 and 2,000 A dc at up to 1,000 V ac
Parallel bridge rating
8,000 A dc at up to 1,500 V ac, with up to 6 bridges
Forcing requirements
150% of design Amperes (EDA) for 30 s at 40 ºC
Power Sources
Power for the PCM – Voltage source
Auxiliary bus
Generator terminals
Compound Source
600 or 1,000 V versions
Power for the PCM – VA (power)
3,251 KVA (1,000 V version)
Power for the PCM - Frequency
3-phase 50/60 Hz, ± 5%
Power to the Cooling Fans (3)
10 A rms, 125 V ac single source
Flashing power
125-250 V dc battery source, with up to 200 A for at least 10 s
380-480 V ac, 50/60 Hz single-phase auxiliary source
Control power  (redundant with 2 bridges,
warm backup}
For two ac sources, or one ac and one dc source
Nominal 120 V ac ±15%, with 1 DACA, 10 A rms max.
Battery source 125 V dc, range 80-140 V dc,
 
10.6 A dc max.
Heat loss in single PCM cabinet
10
 
KW for a 2000 A, 1,000 V ac PCM