Running Hardware Diagnostics
Page 36-6
Running Hardware Diagnostics
The 
test
 command initiates one or more test routines on a switching module that you 
specify. You can also optionally test all switching modules in one test session. Test status, 
instructions, and a summary of results are provided as output. Start a diagnostic test session 
using the following command syntax:
test <slot_number> [<repeat_count> [<test_name>]]
where
<slot_number>
Indicates the slot number in the Omni Switch/Router for the module on 
which you want to run tests. If you enter 
all
 for this parameter, then all 
switching modules in the chassis will be tested. This parameter is required; 
if you do not enter a slot number then the test session will not start.
<repeat_count>
Indicates the number of times to run the specified tests on the module. 
This value can be an integer between 0 and 999. A value of zero (0) 
repeats the test infinitely. The default value is 1. This default will be 
assumed if you do not enter a 
repeat_count
.
<test_name>
 
Indicates the test to be performed on the module. You can indicate the test 
name or 
all
 to run all tests. You can enter only one test name or 
all
. The 
default is 
all
. This default will be assumed if you do not enter a 
test_name
.
 Note ♦
A combination of 
repeat_count
 set to 
0
 and 
test_name
 
set to 
all
 allows the user to run either the port test 
infinitely or all off-board tests infinitely. If the user 
chooses to run the port test when prompted, all the 
static tests (memory and control/status register tests) 
are run once, followed by an infinite run of the port 
test. See Sample Command Lines on page 36-9 for 
more information.
Descriptions of each test follows:
alpreg
Tests the Alpine registers. Test the Alpine control logic, registers, and 
data/address lines.
csr
Tests the command/status registers. Includes testing management bus 
buffers, management bus read/write control logic, reset and 
LED
 memory, 
ID EEPROM
, and reset circuitry.
gigareg
Tests the Giga-Chip registers. Test the Giga-Chip control logic, registers, 
and data/address lines.
hrexmem
Tests the 
HRE-X
’s local memory. Includes testing the 
HRE-X
 read/write 
functions, data/address, and the memory.
hrexport
Tests the 
HRE-X
’s functions. Packets are generated by the 
MPX
, sent out 
to the port, and claimed by the 
HRE-X
. The 
HRE-X
 will insert additional 
routing information to the claimed packet and place it back on 
MVBUS
 to 
be claimed and verified by the 
MPX
. This test can be bypassed. See 
ilb
Performs a port test using the internal loopback at the 
PHY
 or framer 
interface. Packets are generated by the 
MPX
 and sent out to the port and 
returned through an internal loopback within the 
PHY
 or framer. The 
MPX
 
verifies the packets on a bit by bit basis.