Runco SC-1 用户手册

下载
页码 122
Runco SC-1 Owner’s Operating Manual
89 
PRE
L
IMINAR
Y
Figure 5-2. Installing A New Lamp
12. Rest the anode (+) end of the lamp on the lamp cradle as shown in Figure 5-2. Then, 
slip the positive lamp connector over the bulb end. 
13. Tighten the set screws in both negative and positive lamp connectors; see Figure 5-3. 
If you accidentally touch the quartz body of the lamp with your bare hands, clean the 
surface as described in Maintenance and Cleaning on page 85
 
Figure 5-3. Securing Lamp Anode (+) and Cathode (-) Connectors