Air Flow Interlocks: The lamp fan vane switch is located within the lamp cooling 
compartment. The extractor vane switch is located just inside the top exhaust duct on the 
projector. Check and, if necessary, clean the switches to remove accumulated dust or dirt 
that could impede movement. 
Within the exhaust duct connected at the top of the projector, adequate airflow must be 
maintained and routed away from the operating area surrounding the projector. Inspect 
regularly and confirm that:
• There are no obstructions or “kinks” within the ducting.
• All air intake areas of the projection head and ballast are unobstructed.
• Exhaust airflow at the top vent is at least 600 CFM. Make sure lamp wiring does not 
interfere with vane switch operation. Refer to Maintaining Proper Cooling on 
page 84. 
Laminar Airflow Device (LAD): Whenever you check or replace the air filter on the side 
of the projector, also visually check the small square laminar airflow device just beyond the 
filter opening. The LAD should be nearly white in color. If it is very dark (rare), it may need 
to be replaced by a qualified service technician. Contact Runco or your dealer. 
5.4 
Lamp and Filter 
Replacement
The SC-1 uses a xenon lamp to deliver its high brightness. The lamp should be replaced 
when it reaches the end of its life (typically 1000 hours), or sooner if a noticeable 
degradation in brightness occurs. When you replace a lamp, you should replace the air 
filter as well. 
Keep track of the number of hours the lamp has been in use and be aware of any changes 
to brightness. These indicators will help you effectively maintain operation of the projector. 
To find out how long the currently-installed lamp has been in service, select Lamp Hours 
from the DHD Controller Installation menu (available by selecting Service -> Display 
Device -> Configure -> Installation
, in sequence). 
Lamp Replacement
For lamp or filter replacement, please contact your nearest Runco authorized 
service center or Runco dealer. Do not attempt to replace the lamp yourself!
1.
Turn off the projector. Allow the projector cooling fans to run for at least 10 minutes 
prior to disconnecting the power cord and removing the lamp assembly for 
replacement.
2.
Disconnect the AC power cord from the projector.
3.
Remove the screw holding the lamp/air filter cover in place. Then, lift the cover up and 
away from the projector (see Figure 3-6). 
4.
Turn the knob to open the inner lamp cooling compartment and reveal the cathode 
end (–) of the lamp (see Figure 3-6). 
Xenon arc lamps are under high pressure and must be handled 
with great care at all times. Lamps may explode if dropped or 
mishandled. Allow the lamp to cool completely before attempting to 
remove it. 
Never open the lamp door unless you are wearing protective 
clothing. Recommended protective clothing includes — but may 
not be limited to — protective gloves, latex lab gloves, a 
double-layer 0.040” acetate face shield, and a quilted ballistic nylon 
jacket or welder’s jacket. 
WARNING