Viking 855 用户手册

下载
页码 16
SECTION  TSM
685.2
ISSUE
C
PAGE  8 OF  16
Buttonhead 
Screws
Locknut
Inner Magnet
Set Collar
Canister 
Bushing
Canister
O-ring
Button Head 
Screws
Canister and Casing  
Drain Holes
DISASSEMBLY Of COUPLING
fIGURE 9
PUMP, INNER MAGNET AND CANISTER ASSEMBLY 
Series MD2-B and MD2-C, All Sizes
1.  Remove  the  piping  to  the  ports  and  remove  the 
capscrews securing the pump to the bracket.  Support 
the pump with an overhead hoist if possible.  Use the 
M10  x  120  capscrew  (jackscrew)  in  the  bracket  to 
separate the inner magnet from the outer.  
(See figure 
Sequence 10).
CAUTION !
Use  extreme  caution,  when  pulling  the  in-
ner magnet away from the outer magnet (see 
figure 10). Do not place your fingers between 
the  pump mounting flange and the face of the 
bracket.  If you do not completely pull the pump 
out it will snap back and could pinch a finger or 
hand. Once the inner magnet is removed from 
the bracket be careful setting it down as it will 
attract any iron or steel object.
2.   The canister will contain some liquid, therefore use care 
while removing from the pump and pull it straight off.
fIGURE 12
MOTOR (OR BEARING CARRIER) AND BRACKET 
fIGURE 11
INNER MAGNET AND LOCKNUT ASSEMBLY
Motor or 
Bearing 
Carrier
Bracket
Capscrews
3.   Remove the two 6mm buttonhead machine screws and 
the set collar. Insert a brass bar through a port between 
two rotor teeth and remove the locknut 
(See figure 11). 
Slide the inner magnet off the shaft. Do not forget this 
is a very strong magnet. If further pump disassembly is 
required, refer to Step 7 of 
PUMP DISASSEMBLY.
fIGURE 10
PUMP AND BRACKET SEPARATION SEQUENCE 
M10x120 CAPSCREW
DO NOT PLACE 
fINGERS HERE
M10x120 CAPSCREW
DO NOT PLACE 
fINGERS HER
E
(4) 12mm Screw
4.   Do  not  remove  the  O-ring  unless  it  is  bad,  especially 
if  PTFE  (derivative)  encapsulated.  If  a  new  O-ring  is 
required, follow instructions in the 
ASSEMBLY section 
on
 page 10.
5.  You should be able to visually inspect the outer magnets 
from  the  end  of  the  bracket.  If  removal  is  necessary, 
start  by  removing  the  (4)  capscrews 
(See  figure  12) 
and  separate  the  bracket  from  the  motor  or  bearing 
carrier. Loosen the 2 setscrews on the outer shell hub 
and  slide  the  outer  magnet  assembly  off  the  shaft.  If 
the unit features a bearing carrier, 
refer to Page 9  for 
disassembly of the bearing carrier housing.