Xerox 2750 用户手册

下载
页码 43
2750 op#4 R3.doc  10-02 
 
Page 4-2
 
Passwords 
 
Certain menu items displayed on the control panel are password protected for the KEY 
OPERATORS and TECHNICIAN ONLY
. Untrained persons adjusting parameters can cause a 
great deal of damage to the folder. For each of these, the user will be prompted to enter the 
password. Use the number 
1
 button (
up
) until the appropriate number is reached, then press the 
number 
3
 button (
set/enter
). You now have access until either of two events occurs: Power to the 
folder is cycled on/off; or, a 10 minute interval passes with the keypad in the operators fold 
selection (default) mode. In either event, the keypad will return to a locked state requiring re-entry 
of the password. 
 
 
 
System Menu
 
Page 1 
1: Communications 
mode 
2:  Infeed jog Fwd 
 
Jam clearance – drives infeed motor forward 
3:  Infeed Jog Rev 
 
Jam clearance – drives infeed motor in reverse 
4: Parameters 
Page 2 
1: Device 
Test 
2: Assign 
folds 
3: Assign 
handfeeds 
4: Recent 
errors 
Page 3 
1: Stack 
sensor 
2: Quit 
 
Communications mode 
Page 1 
1:  NORMAL = Normal printer/folder communications 
2:  USE KEYPAD FOLDS = Overrides Controller fold selections, but maintains communications 
(e.g., for job recovery) 
3:  NONE = Serial port disconnected (comms OFF) 
4: LOOPBACK 
TEST 
Communications test 
Page 2 
1: Quit 
 
Jog functions 
These are accessible to the operator - no password required. 
 
Parameter viewing and modification 
Viewing - unrestricted access 
Modification - technician only 
 
 
 The Key Operator Password can be obtained from your service technician.
 
Substitutes for an LED. Displays the status of the photosensor at the tower exit: 1 
= open (no paper present), 0 = covered (paper detected).