Diagnostic Error Code
FRU/Action
001-027-XXX System Configuration/Setup error
1. Run Setup
2. Flash the system. See “Updating (flashing) BIOS
3. System board
001-032-XXX System Device Controller failure
System board
001-034-XXX System Device Buffer Allocation failure
1. Reboot the system
2. Flash the system. See “Updating (flashing) BIOS
3. Run memory test
4. System board
001-035-XXX System Device Reset condition detected
System board
001-036-XXX System Register error
System board
001-038-XXX System Extension failure
1. Adapter card
2. System board
001-039-XXX System DMI data structure error
1. Flash the system. See “Updating (flashing) BIOS
2. System board
001-040-XXX System IRQ failure
1. Power-off/on system and re-test
2. System board
001-041-XXX System DMA failure
1. Power-off/on system and re-test
2. System board
001-195-XXX System Test aborted by user
Information only Re-start the test, if necessary
001-196-XXX System test halt, error threshold exceeded
1. Press F3 to review the log file
2. Re-start the test to reset the log file
001-197-XXX System test warning
1. Make sure the component that is called out is
2. Re-run test
3. Replace the component that is called out in warning
statement
4. Replace the component under test
001-198-XXX System test aborted
1. If a component is called out, make sure it is
2. Flash the system and retest. See “Updating (flashing)
001-199-XXX System test failed, cause unknown
2. Flash the system and re-test
3. Replace component under function test
001-250-XXX System ECC error
System board
001-254-XXX 001-255-XXX 001-256-XXX 001-257-XXX
System DMA error
System board
001-260-XXX 001-264-XXX System IRQ error
System board