Galil DMC-1400 用户手册
DMC-1400 Series Command Reference TI
● 197
TI
FUNCTION: Tell Inputs
DESCRIPTION:
This command returns the state of all 7 general digital inputs or 3 inputs for the DMC-1425.
Response is a decimal number which when converted to binary represents the status of all
7 digital inputs.
7 digital inputs.
BIT TI
Bit 6
Input 7
Bit 5
Input 6
Bit 4
Input 5
Bit 3
Input 4
Bit 2
Input 3
Bit 1
Input 2
Bit 0
Input 1
ARGUMENTS: TI
USAGE:
While Moving
Yes
Default Value
---
In a Program
Yes
Default Format
3.0
Command Line
Yes
Can be Interrogated
Yes
Used as an Operand
Yes
Controller Usage
ALL
OPERAND USAGE:
_TI contains the status byte of the input block. Note that the operand can be masked to return
only specified bit information - see section on Bitwise operations
EXAMPLES:
TI
08
08
Input 4 is high, others low
TI
00
00
All inputs low
Input =_TI
Sets the variable, Input, with the TI value
TI
127
127
All inputs high