CHAPTER 2
NETWORK REQUIREMENTS
Before installing Cabletron Systems 7F06-02 Module, review the
network requirements outlined in this chapter. All requirements
included in this chapter should be met to ensure satisfactory
performance of the 7F06-02 Module. Failure to do so may result in
unsatisfactory network performance.
network requirements outlined in this chapter. All requirements
included in this chapter should be met to ensure satisfactory
performance of the 7F06-02 Module. Failure to do so may result in
unsatisfactory network performance.
Appendix A
2.1 FPIM MODULE SPECIFICATIONS
This module uses Fiber Port Interface Modules (FPIM) to provide
front panel cable connections. The FPIMs are user-installable. See
Section 3.2
front panel cable connections. The FPIMs are user-installable. See
Section 3.2
2.1.1 FPIM-00 and FPIM-01
The FPIM-00 and FPIM-01 provide a multimode fiber connection.
The FPIM-00 uses a MIC style connector and the FPIM-01 uses an
SC type connector. The specifications for both devices are listed in
Table 2-1.
The FPIM-00 uses a MIC style connector and the FPIM-01 uses an
SC type connector. The specifications for both devices are listed in
Table 2-1.
Table 2-1. FPIM-00 and FPIM-01 Specifications
Parameter
Typical
Value
Worst
Case
Worst
Case
Budget
Typical
Budget
Receive
Sensitivity
Sensitivity
-30.5 dBm
-28.0 dBm
—
—
Peak Input
Power
Power
-7.6 dBm
-8.2 dBm
—
—