Chapter 2
Using the SCXI-1127/1128
2-24
ni.com
Figure 2-21.  SCXI-1332 Connected to an SCXI-1127/1128 Schematic
Matrix Expansion
You can build matrices larger than 4 
× 8 by using multiple 
SCXI-1127/1128 modules. You can build these larger matrices using row 
and column expansion of the 4 
× 8 matrix. An example of row expansion 
is an 8 
× 8 matrix. A 4 × 16 matrix is an example of a column expansion. 
A 8 
× 16 matrix is an example of both a row and column expansion.
Figure 2-22 shows an example of two SCXI-1332 terminal blocks 
connected to form an 8 
× 8 matrix. You can connect the terminal blocks 
using matrix expansion cables that are available from National Instruments. 
The columns of one module are connected to the other module, doubling 
the number of rows from four to eight. Figure 2-23 shows the schematic 
of an 8 
× 8 matrix made this way. The rows in module 2 are now rows 
R4 through R7 due to the matrix expansion. Similarly, you can make a 
4
× 16 matrix by connecting the rows of two SCXI-1332s.
Power
Supply
DMM
Load Resistors
c0
c1
c2
c3
c4
c5
c6
c7
r 0
r 1
r 2
r 3
+
+