Power supply
The server has two hot-swap power supply module bays on the rear
panel that accept hot-swap redundant power supply modules. The
system ships out with two power supply modules installed. A
redundant power configuration enables a fully-configured system to
continue running even if one power supply module fails.
panel that accept hot-swap redundant power supply modules. The
system ships out with two power supply modules installed. A
redundant power configuration enables a fully-configured system to
continue running even if one power supply module fails.
WARNING! To reduce the risk of personal injury or damage to
the equipment, the installation of power supply modules
should be referred to individuals who are qualified to service
server systems and are trained to deal with equipment capable
of generating hazardous energy levels.
the equipment, the installation of power supply modules
should be referred to individuals who are qualified to service
server systems and are trained to deal with equipment capable
of generating hazardous energy levels.
WARNING! To reduce the risk of personal injury from hot
surfaces, observe the thermal labels on each power supply
module. You can also consider wearing protective gloves.
surfaces, observe the thermal labels on each power supply
module. You can also consider wearing protective gloves.
WARNING! To reduce the risk of personal injury from electric
shock hazards, do not open the power supply modules. There
are no serviceable parts inside the module.
shock hazards, do not open the power supply modules. There
are no serviceable parts inside the module.
Caution! Electrostatic discharge can damage electronic
components. Make sure that you are properly grounded
before handling a power supply module.
components. Make sure that you are properly grounded
before handling a power supply module.
Caution! Due to chassis airflow disruption, a power supply
bay should never be vacant for more than two minutes when
the server is powered on. Exceeding five minutes might cause
the system to exceed the maximum acceptable temperature
and possibly damage the system components.
bay should never be vacant for more than two minutes when
the server is powered on. Exceeding five minutes might cause
the system to exceed the maximum acceptable temperature
and possibly damage the system components.
Caution! The system does not support running with only one
power supply. To prevent chassis airflow disruption, a power
supply bay should never be vacant for more than two minutes.
Exceeding the time may cause the system to exceed the
maximum acceptable temperature and possibly damage
system components.
power supply. To prevent chassis airflow disruption, a power
supply bay should never be vacant for more than two minutes.
Exceeding the time may cause the system to exceed the
maximum acceptable temperature and possibly damage
system components.
Caution! The system operating voltage range is 200 to 240
VDC. Do not plug the power cord into an incorrect voltage
voltage source.
VDC. Do not plug the power cord into an incorrect voltage
voltage source.