Lucent Technologies 555-233-115 用户手册

下载
页码 502
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  
555-233-115  
Issue 1
April 2000
Adding or Removing Cabinet Hardware 
6-76
Add IP Interface Assembly 
6
Upgrade to TN802B (R8)
NOTE:
The upgrade takes about 20 minutes.
1. Insert the flash disk into the right most slot on the TN802 IP trunk. On the 
monitor, a dialog box assigns a drive letter with the removable media 
designation; the default is D:. 
2. Right click on Start > Explore to open the Windows NT Exploring pane 
and select the drive letter indicated in step 1.
3. Double-click on Medpro and select the Setup icon.
4. Follow the Install Shield procedure to transfer all the necessary files to the 
TN802 IP Interface. 
NOTE:
In the Finish dialog box, select 
I will restart later
. Do not 
select 
Restart computer
.
This would be a good time to read the Readme.txt file.
5. Click on Start > Settings > Control Panel > Services.
6. Select IP Trunk and click on Startup.
NOTE:
Do not click on Start.
7. Under Startup Type, select Disabled and click OK to disable IP Trunk 
mode.
NOTE:
If IP trunk and MedPro services are both set to automatic, the 
TN802B defaults to IP Trunk and MedPro features cannot be used.
8. Select MedPro and click on Startup.
NOTE:
Do not click on Start.
9. Under Startup Type, select Automatic and click OK to enable MedPro 
mode.