Canon GM-1000 用户手册

下载
页码 140
 
CANON  Digital Galvano Scanner System  GM-1000 Series 
Users Manual 1.20 
 
 
 
  
96
ID 
Command Name 
Data
Data 
Return Value 
 
40 
Monitor Output Selection A2 
(A8) 
Yes
0: Head1 A phase signal 
1: Head2 A phase signal 
2: Corrected A phase signal 
3: Deviation signal 
 
41 
Monitor Output Selection A3 
(A9) 
Yes
0: Current position signal 
1: Velocity signal 
2: Corrected encoder count 
3: Encoder interpolation data 
 
42 
Monitor Output Selection A4 
(A10) 
Yes
0: Head1 B phase signal 
1: Head2 B phase signal 
2: Corrected B phase signal 
3: Target position signal 
 
43 
Monitor Output Select Check 
Yes
0: A2 (A8) Monitor 
1: A3 (A9) Monitor 
2: A4 (A10) Monitor 
 
44 
Monitor Magnification Setting 
A2 (A8) 
Yes
N: Magnification (x 2
N
 
45 
Monitor Magnification Setting 
A3 (A9) 
Yes
N: Magnification (x 2
N
 
46 
Monitor Magnification Setting 
A4 (A10) 
Yes
N: Magnification (x 2
N
 
47 
Monitor Magnification Check 
Yes
0: A2 (A8) Monitor Magnification 
1: A3 (A9) Monitor Magnification 
2: A4 (A10) Monitor Magnification 
 
161 
Counter Clear Timing 
Yes
0: Axis 1 
1: Axis 2 
0 or 1