Canon GM-1000 用户手册

下载
页码 140
 
CANON  Digital Galvano Scanner System  GM-1000 Series 
Users Manual 1.20 
 
 
 
  
99
Command ID 
10 
Command 
Name 
Target Value Setting Mode 
Data 
0: Absolute position 
1: Relative position 
Return 
Value 
0: Command execution successful 
1: Command execution unsuccessful 
Explanation 
This command is used to specify a position coordinate system for setting by “Command 
ID = 20: Target Position Setting.” 
Before setting a target position, this command should be executed. 
Absolute position: Position with the origin as 0 
Relative position: Distance from the current position 
This command should be executed each time a target position is set because its setting 
is not retained after the start of movement. 
 
Related 
Command 
Step movement procedure 
Command ID = 10: Target Value Setting Mode 
   
Command ID = 20: Target Position Setting 
    Command ID = 8    Data = 0: Movement Start 
 
Command ID 
11 
Command 
Name 
Thermistor Temperature Read 
Data 
0: Controller temperature 
1: Motor temperature 
Return 
Value 
Thermistor voltage A/D converted value 
Explanation 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Controller Thermistor A/D converted value
0
500
1000
1500
2000
2500
3000
3500
4000
20
30
40
50
60
70
80
90
100
110
Temperature(℃)
A/D converted value
 
Motor Thermistor A/D converted value
0
500
1000
1500
2000
2500
3000
3500
4000
20
30
40
50
60
70
80
90
100
110
Temperature(℃)
A/D converted value