GAS KETTLES 
 
 
VENTING 
 
While the kettle is cold, check the vacuum/pressure gauge. The gauge should be in the vacuum zone 
measuring between  20 to 30 in. Hg (84 to 100kPa). If not, there is air in the jacket and  it must be 
removed  by  venting for proper heating. Perform the venting procedure  located  in the  Maintenance 
section of this manual. 
 
 
RESERVOIR JACKET WATER LEVEL CHECK 
 
During use, the reservoir water level must be maintained high to cover the entire heating zone. If the 
low water light is illuminated during use, perform the Filling the Reservoir Jacket procedure located in 
the Maintenance section of this manual. 
 
 
TILTING KETTLES 
 
The low water indicator light (red) should not be lit when kettle is in upright position during operation. 
This light indicates that the burner has been automatically shut off by the kettle’s safety circuitry. It 
is, however, normal for the low water light (red light) to come on when the kettle is in a tilted position. 
 
 
OPERATING DATA 
 
MODEL NO. 
GALLONS OF WATER 
BURNER 
INPUT 
BTU/HR 
HEAT UP TIME-MINUTES 
WORKING 
CAPACITY 
JACKET 
CHARGE 
EMPTY 
TO 5 PSI 
2/3 FULL 
130˚F RISE 
K20GLT/K20GLT 
20 
100,000 
10 
20 
K40GLT/K40GLT 
40 
100,000 
10 
40 
K60GL/K60GLT 
60 
100,000 
15 
60