Checking at abnormal end 
a)  When sense data can be obtained with the REQUEST SENSE command, analyze the sense 
data and retry recovery for a recoverable error.  Refer to Chapter 5 "Sense Data Error 
Recovery Methods" of the SCSI Logical Interface Specifications for further details. 
 
b)  Check the following items for the SCSI cable connection: 
 
• 
All connectors including other SCSI devices are connected correctly. 
• 
The terminating resistor is mounted on both ends of the cable. 
• 
Power is connected to the terminating resistor. 
c)  Check the setting of the terminals.  Note that the checking procedure of SCSI connection 
differs depending on the setting of the motor start mode and UNIT ATTENTION report 
mode. 
 
 
5.6.3 Formatting 
 
Since the HDD is formatted with a specific (default) data format for each model (part number) 
when shipped from the factory, the disk need not be formatted (initialized) when it is installed in 
the system. 
 
However, when the system needs data attributes different from the default format, all recording 
surface of the disk must be formatted (initialized) according to the procedures below. 
 
The user can change the following data attributes at initialization: 
•  Logical data block length 
•  Number of logical data blocks in the user space 
 
This section outlines the formatting at installation.  Refer to Subsection 3.1.5 "MODE SELECT 
(15) ", 3.1.6 "MODE SELECT EXTENDED (55) ", 3.3.1 "FORMAT UNIT (04) ", and Chapter 6 
"Disk Media Management" of the SCSI Logical Interface Specifications for further details. 
 
(1) MODE 
SELECT/MODE 
SELECT EXTENDED command 
 
Specify the format attributes on the disk with the MODE SELECT or MODE SELECT 
EXTENDED command.  The parameters are as follows. 
 
a. Block 
descriptor 
 
 
Specify the size (byte length) of the logical data block in the "data block length" field.  To 
explicitly specify the number of logical data blocks, specify the number in the "number of data 
blocks" field.  Otherwise, specify 0 in "number of data blocks" field.  In this case, the 
currently set value is used. 
C141-E270 
87