Husqvarna R120S 用户手册

下载
页码 88
18 – 
English
Maintenance
Maintenance schedule
The following is a list of the maintenance which should be conducted on the machine. For those points not described in this manual, 
visit an authorised service workshop.
1)
First change after 8 hours. When operating with a heavy load or at high ambient temperatures, replace every 25 hours. 
2)
Clean 
and replace the filter more often in dusty conditions. 
3)
If the machine is used daily it should be lubricated twice a week. 
4)
Conducted 
by authorised service workshop.
X = Described in this operator's manual
O = Not described in this operator's manual
Maintenance
Daily maintenance 
before starting
At least once 
a year
Maintenance 
interval in hours
25
50
100 200
Cleaning
X
Check the engine’s oil level
X
Check the engine’s cooling air intake
X
Check the steering wires
X
Check the battery
X
Check the safety system
X
Check nuts and screws
O
Check for fuel and oil leakage.
O
Clean around the muffler
O
Change engine oil 
1)
X
X
Replace the air filter’s prefilter2)
X
Check the cutting deck
X
Check the tire pressures.
X
Lubricate joints and shafts 
3)
X
Check the V-belts
O
Checking and adjusting of throttle wire
X
Replace the air filter’s pre-filter and paper filter 
2)
X
Replace the fuel filter
X
Replace the spark plug.
X
Check the fuel hose. Replace if necessary .
4)
O
!
WARNING! No service procedures must be 
conducted on the engine or cutting unit 
unless:
The engine is switched off.
The ignition key is removed.
The ignition cable has been removed from 
the spark plug.
The parking brake is applied.
The cutting unit is disengaged.