Topcon GPT-2000 用户手册

下载
页码 168
2-9
   2 PREPARATION FOR MEASUREMENT
2.8
Laser Plummet ON/OFF (Only for Laser Plummet type)
Laser plummet option will help you to center the instrument easily onto the measurement point. 
There are two ways to turn on/off of laser plummet option as follows.
On/Off of laser plummet option by Soft Key in Tilt Correction  
On/Off of laser plummet option from MENU mode  
Laser Plummet auto-cut off function
The laser plummet will be turned off automatically after 1 to 99 minutes (Default :3 minutes). It is also 
possible to stop the auto-cut off function. 
Refer to Chapter 16 “SELECTING MODE”  to change the time or to invalidate the function.
Operating procedure
Option
Display
1
Press the [F4]  key to get the  function page 2.
[F4]
2
Press the [F1](TILT) key.
In case ON is already selected, the display shows 
tilt correction value.
[F1]
3
Press the [F4](L.PL) key.
By pressing the [F4](L.PL) key, the laser plummet 
will be turned On / Off alternately.
[F4]
Symbol mark while the laser is emitting.
The following symbol mark will appear at the right side of the second line. 
Operating procedure
Operation
Display
1
Press the [MENU] key.
[MENU]
2
Press the [F4](P
) key to get the menu on page 2.
[F4]
3
Press the [F3] key.
[F3]
4
Press the [F1] or [F2] key to turn on or off the laser 
plummet option.
[F1] or [F2]
V :   90°10'20" 
HR:  120°30'40"
0SET  HOLD HSET  P1
TILT   REP   V%  P2
TILT SENSOR:[XY-ON]
X:-0°00'25"
Y: 0°00'20" 
X-ON XY-ON OFF L.PL
TILT SENSOR:[XY-ON]
X:-0°00'25"       
Y: 0°00'20" 
X-ON XY-ON OFF L.PL
TILT SENSOR:[XY-ON]
X:-0°00'25"       
Y: 0°00'20" 
X-ON XY-ON OFF L.PL
  
MENU            1/3
 F1:DATA COLLECT
 F2:LAYOUT
 F3:MEMORY MGR. P
  
MENU            2/3
 F1:PROGRAMS
 F2:GRID FACTOR
 F3:LASER PLUMMET P
  
LASER PLUMMET  [OFF]
 F1:ON
 F2:OFF
  
LASER PLUMMET  [ON]
 F1:ON
 F2:OFF
Symbol mark