Topcon GPT-2000 用户手册

下载
页码 168
 
3-2
 
   3 ANGLE MEASUREMENT
 
3.2
Switching Horizontal Angle Right/Left
 
Make sure the mode is  Angle measurement.
 
3.3
Measuring from the Required Horizontal Angle
 
3.3.1 Setting by Holding the Angle
 
Make sure the mode is angle measurement
 
.
 
Operating procedure
Operation
Display
 
1
 
Press the [F4](
 
 
) key twice to get the function
on page 3.
[F4]
twice
 
2
 
Press the [F2](R/L) key.
The mode Horizontal angle Right (HR)
switches to (HL) mode.
[F2]
 
3
 
Measure as HL mode.
 
 
Every time pressing the [F2](R/L) key, HR/HL mode switches.
 
Operating procedure
Operation
Display
 
1
 
Set the required horizontal angle, using
Horizontal tangent screw
 
Display angle
 
2
 
Press the [F2](HOLD) key.
[F2]
 
3
 
Collimate the target.
Collimate
 
4
 
Press the [F3](YES) key to finish holding the 
horizontal angle.*1)
The display turns back to normal angle 
measurement mode.
[F3]
*1) To return to the previous mode, press the [F4](NO) key.
 V :  90°10'20"
 HR: 120°30'40"
0SET  HOLD HSET  P1
TILT   REP   V%  P2
H-BZ   R/L CMPS  P3
 V :  90°10'20"
 HL: 239°29'20"
H-BZ   R/L CMPS  P3
 V :  90°10'20" 
 HR: 130°40'20"
0SET HOLD HSET P1
H ANGLE HOLD
HR= 130°40'20"
> SET ?
 --- --- [YES][NO]
 V :  90°10'20" 
 HR: 130°40'20"     
0SET HOLD HSET P1