Topcon GPT-2000 用户手册

下载
页码 168
4-8
   4 DISTANCE MEASUREMENT
The horizontal distance from the instrument to the 
prism will be measured.
5
Collimate point A
0
 using the horizontal motion 
clamp and horizontal tangent screw.
Collimate 
A
0
6
Show the relative elevation of point A
0
.
  [
7
Show the slope distance of point A
0
.
Each time pressing the [
] key, horizontal 
distance, relative elevation and slope distance are 
shown in sequence.
  [
8
Show N coordinate of point A
0
 or A
1
.
Each time pressing [
] key, N,E and Z 
coordinate are shown in sequence.
 [
]
To return to procedure 
4
, press the  [F1](NEXT) key.
To return to the previous mode, press the [ESC] key.
To select the Non-prism or Prism mode, press the  [F3](NP/P) key  after the step 4.  
OFFSET-MEASUREMENT
 HR:   110°20'30" 
 HD:      56.789 m
NEXT  ---  ---  ---
OFFSET-MEASUREMENT
 HR:   113°30'50" 
 HD:      56.789 m
NEXT  ---  ---  ---
OFFSET-MEASUREMENT
 HR:   113°20'30" 
 VD:       3.456 m
NEXT  ---  ---  ---
OFFSET-MEASUREMENT
 HR:   113°20'30" 
 SD:      56.894 m
NEXT  ---  ---  ---
OFFSET-MEASUREMENT
 HR:   113°20'30" 
 N :     -12.345 m
NEXT  ---  ---  ---