Topcon GPT-2000 用户手册

下载
页码 168
4-9
   4 DISTANCE MEASUREMENT
4.7.2 Distance Offset Measurement
Measuring distance and coordinate of the center of a pond or a tree of which the radius is known.
Measuring the distance or coordinate till P0 point, input 
 
oHD value as an offset value and measure P1 
point showing as following draw in distance offset measurement. The display shows distance or 
coordinate value until P0 point.
When setting the coordinate value for the occupied station, refer to Section 5.1 “Setting Coordinate 
Values of Occupied Point”.
Operating procedure
Operation
Display
1
Press the [F4](P1
) key from distance measuring 
mode to get the function on page 2.
[F4]
2
Press the [F1](OFSET)  key.
[F1]
3
Press the [F2](DIST. OFFSET)  key.
[F2]
4
Press the [F1](INPUT) key and enter a offset 
value, and press the [F4](ENTER) key.
[F1]
Offset 
value
[F4]
5
Collimate prism P1, and press the [F1](MEAS) 
key.
Measuring will start.
Collimate 
P1
[F1]
Occ. Point
oHD < 0
oHD >0
P1
P1
P0
In case the measuring  point of (P1) is front side than that of requiring 
point of (P0), the offset value shall be plus, and if it is rear side, the 
offset value shall be minus.
HR:  120°30'40" 
HD:     123.456 m
VD:       5.678 m
MEAS  MODE  NP/P P1
OFSET S.O   S/A  P2
OFFSET           1/2
 F1:ANG.OFFSET
 F2:DIST.OFFSET
 F3:PLANE OFFSET  P
DISTANCE OFFSET
 INPUT FORWARD HD 
oHD:           m
INPUT ---  --- ENTER
DISTANCE OFFSET
 HR:  80°30'40" 
 HD:           m
MEAS  ---  NP/P ---
DISTANCE OFFSET
 HR:  80°30'40" 
 HD* [n]    << m
>Measuring...