Garmin 190-01166-02 用户手册

下载
页码 48
0
GHP 10 Marine Autopilot System Installation Instructions
Appendix
Specifications
ECu
Physical
Dimensions (W×H×D):  6 
19
/
32
 × 4 
19
/
32
 × 2 in. (167.6 × 116.8 × 50.8 mm)
Weight:  1.5 lb. (0.68 kg)
temperature Range: 
from 5°F to 131°F (from -15°C to 55°C)
Case Material:  Fully gasketed, high-impact aluminum alloy, waterproof to IEC 529 IPX7 standards
Power Cable Length: 
9 ft. (2.7 m)
Power
Input Power: 
11.5–14 Vdc prior to serial number 19E002748
 
 
 
11.5–28 Vdc after serial number 19E002748 (only with CCU software version 2.70 or later)
Fuse:   
40 A
Main Power Usage: 
1 A (not including the pump)
CCu
Physical
Dimensions: 
19
/
32
 in. diameter (91.4 mm)
Weight:  5.6 oz. (159 g)
temperature Range: 
from 5°F to 131°F (from -15°C to 55°C)
Case Material:  Fully gasketed, high-impact plastic alloy, waterproof to IEC 529 IPX7 standards
CCU/ECU Interconnect Cable Length: 
16 ft. (5 m)
Power
nMeA 2000 Power Input: 9–16 Vdc
nMeA 2000 Len: 
2 (100 mA)
1.2L/2.0L Pump
Physical
Dimensions (W×H×D):  11 × 4 
11
/
16
 × 3 
11
/
16
 in. (279.4 × 119.4 × 94 mm)
Weight:  8.05 lb. (3.65 kg)
temperature Range: 
From 5°F to 131°F (from -15°C to 55°C)
Cable Length:  19 in. (0.5 m)
Power
Main Power Usage: 
Varies based on hydraulic loading
Compact 2.1L Pump
Physical
Dimensions (W×H×D):  16 
1
/
2
 × 6 × 7 
1
/
2
 in. (420 ×150 × 190 mm)
Weight:  17.6 lb. (8 kg)
temperature Range: 
From 5°F to 131°F (from -15°C to 55°C)
Cable Length:  19 in. (0.5 m)
Power
Main Power Usage: 
Varies based on hydraulic loading