Activate the System
7-8
September 1995 Issue 1  
5. If all the red lights do not go off, reseat (unplug and reinsert) any 
purple-labeled circuit packs displaying red lights.
!
CAUTION:
To avoid a disk crash, never reseat the DEFINITY AUDIX System 
without first shutting it down. Shut down the DEFINITY AUDIX System 
(and allow the disk to completely spin down) before unplugging the 
DEFINITY AUDIX assembly. See Ap pendix C, "DEFINITY AUDIX 
System Power Procedures" f
or the procedure for manually shutting 
down and powering up DEFINITY AUDIX System. 
!
CAUTION:
Before attempting to reseat white-labeled control circuit packs or the 
purple-labeled tone detector/generator circuit pack (in the 
single-carrier cabinet only), first power down the switch.
6. If the red lights still do not go off, read the note below and then refer to 
DEFINITY Communications System Generic 1 and Generic 3i/s/vs 
Maintenance
, 555-204-105, to resolve the trouble, if necessary.
NOTE:
Ignore the red alarm indication light on the TN767 or TN464 DS1 
circuit pack until after the Digital Service Level 1 (DS1) circuit pack is 
administered.