AT&T 555-230-894 用户手册

下载
页码 332
Set Required Country Options
September 1995 Issue 1 
7-7
3. The default is Mu-Law.  If your country uses A-Law companding, type 
A-Law.  If it uses Mu-Law and Mu-Law is displayed, go to Step 4 below. 
Companding mode can be A-law or Mu-law. The switch should have been 
shipped with the correct Tone Detector circuit packs for your country. If 
you have TN420C you must use A-law.  If you have TN748 or TN756 you 
must use  Mu-law. If you have TN2182, then your companding mode is 
dictated by your local practices.  Administering the correct companding 
mode will turn off any red lights on these circuit packs or on the tone-clock 
boards (for example TN780).
4. Press 
ENTER
 when this information is correct.
Other items eventually need to be entered on this screen, but this is all that 
must be done to turn the red alarm indication lights off.  Refer to Table 7-1 
for a list of the country codes.
change system-parameters country-options               Page 1 of 21
SYSTEM PARAMETERS COUNTRY-OPTIONS
         Companding Mode: A-Law           Base Tone Generator Set: 1
     440Hz PBX-dial Tone? n                   Secondary-dial Tone? n
       Digital Loss Plan: 1
  Analog Ringing Cadence: 1    Set Layer 1 timer T1 to 30 seconds? n
Analog Line Transmission: 1
TONE DETECTION PARAMETERS
Tone Detection Mode: 5            Dial Tone Validation Timer 
(msec):                      Interdigit Pause: