Install Initialization and Administration System (INADS) 
Interface
Issue 1  September 1995 
9-21
Install Initialization and 
Administration System (INADS)
Interface
The Initialization and Administration System (INADS) provides a 1200 Bits Per 
Second (bps) modem connection for the remote management terminal for 
DEFINITY System Generic 3.
Figure 9-9 shows a typical Initialization and Administration System (INADS) 
installation, where the analog port is connected from the switch directly to the 
connectors on the auxiliary cable pins. 
Figure 9-9.
Analog Port Connection
As an alternative, Figure 9-10 illustrates a switched connection to the 
Initialization and Administration System (INADS) interface.
1
2
3
4
G3
T
R
1. Initialization and Administration System 
(INADS) interface on AUX connector 
(see Table 9-6 on page 9-10)
2. Auxiliary cable
3. External analog Central Office (CO) 
trunk
4. Cross-connect field
Figure Notes:
9